| General specifications |
| Switching function |
Normally open (NO) |
| Output type |
Two-wire |
| Rated operating distance |
4 mm |
| Installation |
non-flush |
| Output polarity |
DC |
| Assured operating distance |
0 ... 3.24 mm |
| Actual operating distance |
3.6 ... 4.4 mm typ. |
| Reduction factor rAl |
0.37 |
| Reduction factor rCu |
0.36 |
| Reduction factor r304 |
0.74 |
| Nominal ratings |
| Operating voltage |
5 ... 60 V |
| Switching frequency |
0 ... 1000 Hz |
| Hysteresis |
1 ... 10 typ. 5 % |
| Reverse polarity protection |
reverse polarity tolerant |
| Short-circuit protection |
pulsing |
| Voltage drop |
≤ 5 V |
| Operating current |
2 ... 100 mA |
| Lowest operating current |
2 mA |
| Off-state current |
0 ... 0.5 mA typ. |
| Switching state indicator |
Multihole-LED, yellow |
| Functional safety related parameters |
| MTTFd |
2300 a |
| Mission Time (TM) |
20 a |
| Diagnostic Coverage (DC) |
0 % |
| Approvals and certificates |
| UL approval |
cULus Listed, General Purpose |
| CSA approval |
cCSAus Listed, General Purpose |
| CCC approval |
Certified by China Compulsory Certification (CCC) |
| Ambient conditions |
| Ambient temperature |
-25 ... 70 °C (-13 ... 158 °F) |
| Mechanical specifications |
| Connection type |
Connector M12 x 1 , 4-pin |
| Housing material |
brass, nickel-plated |
| Sensing face |
PBT |
| Housing diameter |
12 mm |
| Degree of protection |
IP67 |